{"id":3212,"date":"2026-02-11T13:14:00","date_gmt":"2026-02-11T11:14:00","guid":{"rendered":"https:\/\/icmet.wattmedia.ro\/?page_id=3212"},"modified":"2026-03-12T16:17:08","modified_gmt":"2026-03-12T14:17:08","slug":"laborator-incercari-mare-putere-lmp","status":"publish","type":"page","link":"https:\/\/icmet.wattmedia.ro\/en\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/laborator-incercari-mare-putere-lmp\/","title":{"rendered":"High Power Testing Laboratory for electrotechnical equipment"},"content":{"rendered":"<section>\n<div style=\"text-align: center; background-color: #bcffbc; padding: 30px 20px; margin-bottom: 30px; border-bottom: 1px solid #ccc;\">\n<h1 style=\"color: #003366; margin-top: 0; margin-bottom: 20px; font-weight: bold; text-transform: uppercase; font-size: 1.8em;\">\n            High Power Testing Laboratory for Electrotechnical Equipment<br \/>\n        <\/h1>\n<div style=\"display: flex; justify-content: center; gap: 30px; font-weight: bold; font-size: 1.1em; flex-wrap: wrap;\">\n            <a href=\"#contact\" style=\"color: #003366; text-decoration: underline;\">Contact person<\/a><br \/>\n            <a href=\"#incercari\" style=\"color: #003366; text-decoration: underline;\">TESTING<\/a><br \/>\n            <a href=\"#servicii\" style=\"color: #003366; text-decoration: underline;\">Services offered<\/a><br \/>\n            <a href=\"#referinte\" style=\"color: #003366; text-decoration: underline;\">Reference<\/a><br \/>\n            <a href=\"#publicatii\" style=\"color: #003366; text-decoration: underline;\">Publications<\/a>\n        <\/div><\/div>\n<div style=\"border: 2px solid #003366; padding: 20px; margin-bottom: 40px; background-color: #fff; text-align: center;\">\n<h2 style=\"color: #003366; margin-top: 0; margin-bottom: 20px;\">LMP Overview<\/h2>\n<div style=\"max-width: 800px; margin: 0 auto; position: relative; border: 1px solid #ccc; box-shadow: 2px 2px 10px rgba(0,0,0,0.2);\">\n            <a href=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/high-power-laboratory-icmet-craiova.mp4\" target=\"_blank\" rel=\"noopener\"><br \/>\n                <img decoding=\"async\" src=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/high-power-laboratory-icmet-craiova.jpg\" alt=\"Video prezentare Laborator Mare Putere ICMET\" style=\"width: 100%; height: auto; display: block; opacity: 0.9;\"><\/p>\n<div style=\"position: absolute; top: 50%; left: 50%; transform: translate(-50%, -50%); background-color: rgba(0, 51, 102, 0.8); color: white; padding: 20px; border-radius: 50%; font-size: 2em; width: 80px; height: 80px; display: flex; align-items: center; justify-content: center;\">\n                    \u25ba\n                <\/div>\n<p>            <\/a>\n        <\/div>\n<p style=\"margin-top: 15px; font-style: italic; color: #555;\">\n            Click to watch the video presentation of the High Power Laboratory.\n        <\/p>\n<\/p><\/div>\n<div style=\"margin-bottom: 40px;\">\n<p style=\"font-size: 1.1em;\">The laboratory has been accredited by:<\/p>\n<ul style=\"list-style-type: disc; padding-left: 20px; margin-bottom: 20px;\">\n<li>\n                National Accreditation Network in Romania \u2013 <strong>RENAULT<\/strong>. Member <strong>ILAC<\/strong> and <strong>IT<\/strong>. Accreditation according to <strong>EN ISO\/IEC 17025:2005<\/strong>.\n            <\/li>\n<\/ul>\n<p style=\"font-weight: bold; margin-bottom: 10px;\">International member: CIGRE WG 13.12<\/p>\n<p>\n            <a href=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/lovag-registered-laboratory-v2.pdf\" target=\"_blank\" rel=\"noopener\" style=\"text-decoration: underline; color: #0000FF;\"><br \/>\n                LOVAG Registered Laboratory<br \/>\n            <\/a>\n        <\/p>\n<\/p><\/div>\n<div style=\"border: 2px solid #003366; margin-bottom: 40px; background-color: #fff;\">\n<h2 style=\"background-color: #e6e6fa; color: #003366; padding: 10px; text-align: center; margin: 0; border-bottom: 1px solid #ccc;\">\n            RENAR certification<br \/>\n        <\/h2>\n<div style=\"display: flex; flex-wrap: wrap; justify-content: center; align-items: flex-start;\">\n<div style=\"flex: 1; min-width: 300px; padding: 20px; text-align: center; border-right: 1px solid #eee;\">\n                <a href=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/certificat-de-acreditare-li-004-icmet-craiova.pdf\" target=\"_blank\" rel=\"noopener\"><br \/>\n                    <img decoding=\"async\" src=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/certificat-de-acreditare-li-004-icmet-craiova.jpg\" alt=\"Certificat de Acreditare RENAR LI 004\" style=\"height: 500px; width: auto; max-width: 100%; object-fit: contain; border: 1px solid #ddd; box-shadow: 2px 2px 5px rgba(0,0,0,0.1);\"><br \/>\n                <\/a><\/p>\n<p style=\"margin-top: 15px; font-size: 0.9em; color: #555;\">\n                    <a href=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/certificat-de-acreditare-li-004-icmet-craiova.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color: #003366; text-decoration: underline;\"><br \/>\n                        Click to view the full certificate (PDF)<br \/>\n                    <\/a>\n                <\/p>\n<\/p><\/div>\n<div style=\"flex: 1; min-width: 300px; padding: 20px; text-align: center;\">\n                <a href=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/lovag-registered-laboratory.pdf\" target=\"_blank\" rel=\"noopener\"><br \/>\n                    <img decoding=\"async\" src=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/lovag-registered-laboratory.png\" alt=\"LOVAG Registered Laboratory\" style=\"height: 500px; width: auto; max-width: 100%; object-fit: contain; border: 1px solid #ddd; box-shadow: 2px 2px 5px rgba(0,0,0,0.1);\"><br \/>\n                <\/a><\/p>\n<p style=\"margin-top: 15px; font-size: 0.9em; color: #555;\">\n                    <a href=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/lovag-registered-laboratory.pdf\" target=\"_blank\" rel=\"noopener\" style=\"color: #003366; text-decoration: underline;\"><br \/>\n                        Click to open the document (PDF)<br \/>\n                    <\/a>\n                <\/p>\n<\/p><\/div><\/div><\/div>\n<div id=\"incercari\" style=\"border: 2px solid #003366; padding: 20px; margin-bottom: 40px; background-color: #fff;\">\n<div style=\"display: flex; flex-wrap: wrap; gap: 30px; align-items: center;\">\n<div style=\"flex: 1; min-width: 300px; text-align: center;\">\n                <img decoding=\"async\" src=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/hala-de-incercari-divizia-mare-putere-icmet-craiova.jpg\" alt=\"Hala de incercari Divizia Mare Putere\" style=\"max-width: 100%; height: auto; border: 1px solid #ddd; box-shadow: 2px 2px 5px rgba(0,0,0,0.2);\">\n            <\/div>\n<div style=\"flex: 1; min-width: 300px;\">\n<p style=\"font-weight: bold; margin-bottom: 10px; color: #000;\">\n                    Short-circuit current test parameters:\n                <\/p>\n<table border=\"1\" style=\"width: 100%; border-collapse: collapse; text-align: center; margin-bottom: 30px; font-size: 0.95em;\">\n<thead style=\"background-color: #99ccff; color: #000;\">\n<tr>\n<th style=\"padding: 8px;\">phase<\/th>\n<th style=\"padding: 8px;\">phase<\/th>\n<\/tr>\n<\/thead>\n<tbody style=\"background-color: #e0e0e0;\">\n<tr>\n<td style=\"padding: 8px;\">12 kV \u2013 170 kA<\/td>\n<td style=\"padding: 8px;\">12 kV \u2013 170 kA<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px; vertical-align: middle;\">72.5 kV \u2013 25 kA<\/td>\n<td style=\"padding: 8px;\">123 kV \u2013 25 kA<br \/>170 kV \u2013 15 kA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"font-weight: bold; margin-bottom: 10px; color: #000;\">\n                    Short-time withstand current test parameters:\n                <\/p>\n<table border=\"1\" style=\"width: 100%; border-collapse: collapse; text-align: center; margin-bottom: 10px; font-size: 0.95em;\">\n<thead style=\"background-color: #99ccff; color: #000;\">\n<tr>\n<th style=\"padding: 8px;\">phase<\/th>\n<th style=\"padding: 8px;\">phase<\/th>\n<\/tr>\n<\/thead>\n<tbody style=\"background-color: #e0e0e0;\">\n<tr>\n<td style=\"padding: 8px;\">500V \u2013 135kA\/5s<\/td>\n<td style=\"padding: 8px;\">500V \u2013 320kA\/5s<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">860 V \u2013 80 kA\/5s<\/td>\n<td style=\"padding: 8px;\">2000 V \u2013 80 kA\/5s<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div><\/div>\n<div style=\"text-align: center; margin-top: 40px; padding-top: 20px; border-top: 1px solid #ccc;\">\n            <img decoding=\"async\" src=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/fondul-european-de-dezvoltare-regionala-icmet-craiova.jpg\" alt=\"Sigla POS CCE AXA II\" style=\"max-width: 300px; height: auto; margin-bottom: 15px; border: 1px solid #ddd;\"><\/p>\n<p style=\"font-weight: bold; color: #0000FF; text-decoration: underline;\">\n                Non-reimbursable financing from the European Regional Development Fund.<br \/>\n                For the ICMET Craiova High Power Laboratory.\n            <\/p>\n<\/p><\/div><\/div>\n<div style=\"border: 2px solid #003366; padding: 20px; margin-bottom: 40px; background-color: #fff;\">\n<div style=\"display: flex; flex-wrap: wrap; gap: 30px; align-items: center; margin-bottom: 30px;\">\n<div style=\"flex: 1; min-width: 300px;\">\n<h3 style=\"color: #000; text-align: center; text-transform: uppercase; margin-top: 0; font-weight: bold;\">\n                    DIRECT TESTING SCHEME<br \/>\n                <\/h3>\n<div style=\"background-color: #bcffbc; padding: 15px; border: 1px solid #e0cda0; font-size: 0.95em; line-height: 1.5;\">\n<ul style=\"padding-left: 20px; margin: 0;\">\n<li><strong>Generators:<\/strong> Three short-circuit units. Each has 2500 MVA. The current is 120 kA for 0.5 s. They operate in parallel.<\/li>\n<li><strong>Protection:<\/strong> Six three-phase circuit breaker units. The parameters are 12 kV and 120 kA.<\/li>\n<li><strong>Short circuiters:<\/strong> Nine single-phase units. The parameters are 12 kV and 330 kA.<\/li>\n<li><strong>Step-up transformers:<\/strong> Nine single-phase units of 600 MVA. Ratios 12\/12\/25\/51 kV.<\/li>\n<li><strong>Step-down transformers:<\/strong> Four 40 MVA single-phase units. Multiple ratios.<\/li>\n<li><strong>Cells:<\/strong> Eight test cells available.<\/li>\n<li><strong>Capacitors:<\/strong> Battery for direct testing. Three-phase 36 kV and 400 A.<\/li>\n<li><strong>Heating:<\/strong> Heating test installation. Up to 10,000 A in AC.<\/li>\n<li><strong>Pantograph:<\/strong> IT disconnector installation. Parameters 525 kV and 60 kA\/1s.<\/li>\n<li><strong>Power arc:<\/strong> AC installation For 420 kV insulator strings.<\/li>\n<li><strong>Digital:<\/strong> Digital Measurement System 100 MS\/s. It has 16bit and 24 channels.<\/li>\n<\/ul><\/div><\/div>\n<div style=\"flex: 1; min-width: 300px; display: flex; align-items: center; justify-content: center;\">\n<div style=\"background-color: #fff; padding: 10px; border: 1px solid #ccc; box-shadow: 3px 3px 8px rgba(0,0,0,0.3);\">\n                    <img decoding=\"async\" src=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/trei-generatoare-scurtcircuit-2500-mva-icmet-craiova.jpg\" alt=\"Sala masinilor generatoare\" style=\"max-width: 100%; height: auto; display: block;\">\n                <\/div><\/div><\/div>\n<div style=\"display: flex; flex-wrap: wrap; gap: 20px; justify-content: center;\">\n<div style=\"flex: 1; min-width: 250px; text-align: center;\">\n<div style=\"background-color: #fff; padding: 10px; border: 1px solid #ccc; box-shadow: 3px 3px 8px rgba(0,0,0,0.3); height: 100%; display: flex; align-items: center; justify-content: center;\">\n                    <img decoding=\"async\" src=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/test-arc-electric-lant-izolatoare-compozite-icmet-craiova.jpg\" alt=\"Test arc izolator\" style=\"max-width: 100%; max-height: 250px; width: auto;\">\n                <\/div><\/div>\n<div style=\"flex: 1; min-width: 250px; text-align: center;\">\n<div style=\"background-color: #fff; padding: 10px; border: 1px solid #ccc; box-shadow: 3px 3px 8px rgba(0,0,0,0.3); height: 100%; display: flex; align-items: center; justify-content: center;\">\n                    <img decoding=\"async\" src=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/incercare-arc-electric-intern-celula-medie-tensiune-icmet-craiova.jpg\" alt=\"Incercare arc celula\" style=\"max-width: 100%; max-height: 250px; width: auto;\">\n                <\/div><\/div>\n<div style=\"flex: 1; min-width: 250px; text-align: center;\">\n<div style=\"background-color: #fff; padding: 10px; border: 1px solid #ccc; box-shadow: 3px 3px 8px rgba(0,0,0,0.3); height: 100%; display: flex; align-items: center; justify-content: center;\">\n                    <img decoding=\"async\" src=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/baterie-condensatoare-bobine-reglajul-factorului-de-putere-icmet-craiova.jpg\" alt=\"Baterie condensatoare\" style=\"max-width: 100%; max-height: 250px; width: auto;\">\n                <\/div><\/div><\/div><\/div>\n<div id=\"servicii\" style=\"border: 2px solid #003366; margin-bottom: 40px; background-color: #fff;\">\n<h2 style=\"background-color: #003366; color: white; padding: 10px; text-align: center; margin: 0; border-bottom: 1px solid #ccc; text-transform: uppercase;\">\n            SERVICES OFFERED<br \/>\n        <\/h2>\n<div style=\"background-color: #bcffbc; padding: 20px; font-size: 1.05em; line-height: 1.6;\">\n<h4 style=\"color: #003366; margin-bottom: 10px; border-bottom: 1px solid #ccc; padding-bottom: 5px;\">Standard and Switching Tests<\/h4>\n<ul style=\"padding-left: 30px; margin-bottom: 20px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">Testing the switching capacity of MV and LV circuit breakers and disconnectors. The breaking capacity of fuses is also tested.<\/li>\n<li style=\"margin-bottom: 10px;\">Thermal and dynamic stability tests. These apply to IT and LV devices, cables and cells.<\/li>\n<li style=\"margin-bottom: 10px;\">Dynamic short-circuit stability testing of power transformers. The limit is up to 120 MVA.<\/li>\n<li style=\"margin-bottom: 10px;\">Switching tests for inductive and capacitive currents. Applies to circuit breakers and switch disconnectors.<\/li>\n<li style=\"margin-bottom: 10px;\">Mechanical endurance testing for circuit breakers, disconnectors and contactors.<\/li>\n<\/ul>\n<h4 style=\"color: #003366; margin-bottom: 10px; border-bottom: 1px solid #ccc; padding-bottom: 5px;\">Special and Heating Tests<\/h4>\n<ul style=\"padding-left: 30px; margin: 0; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">Heating tests of current paths of electrical devices and bars. Maximum rated current 10 kA ac.<\/li>\n<li style=\"margin-bottom: 10px;\">Heating tests on power transformers, instrument transformers and reactors.<\/li>\n<li style=\"margin-bottom: 10px;\">Short circuit tests of arresters, armatures and motors. Grounding systems are also tested.<\/li>\n<li style=\"margin-bottom: 10px;\">Special power arc tests. Performed on insulator lines. Includes internal electric arc.<\/li>\n<\/ul><\/div><\/div>\n<div style=\"display: flex; justify-content: center; margin-bottom: 40px;\">\n<div style=\"border: 2px solid #003366; max-width: 800px; width: 100%;\">\n<h3 style=\"background-color: #003366; color: #ffffff; text-align: center; margin: 0; padding: 10px; font-weight: bold; border-bottom: 1px solid #ccc;\">\n                High power testing on site<br \/>\n            <\/h3>\n<div style=\"background-color: #f4f4f4; padding: 20px;\">\n<ul style=\"margin: 0; padding-left: 20px; font-weight: bold;\">\n<li style=\"margin-bottom: 10px;\">Measurement of switching overvoltage when disconnecting inductive and capacitive loads. Applicable in networks up to 420 kV.<\/li>\n<li>Measurement of voltages induced in the load during short circuit on overhead lines with voltages up to 420 kV.<\/li>\n<\/ul><\/div><\/div><\/div>\n<hr style=\"border-top: 1px solid #000; margin: 30px 0;\">\n<div id=\"contact\" style=\"margin-bottom: 40px;\">\n<div style=\"margin-bottom: 20px;\">\n<p style=\"font-size: 1.1em; margin-bottom: 5px;\">Laboratory manager: <strong>Eng. Daniel TRUTA<\/strong><\/p>\n<p style=\"margin: 0;\">\n                <strong>Phone:<\/strong> <a href=\"tel:0351402427\" style=\"color:#000;\">0351 402427<\/a>; <a href=\"tel:0351404888\" style=\"color:#000;\">0351 404888<\/a><br \/>\n                <strong>e-mail:<\/strong> <a href=\"mailto:lmp@icmet.ro\" style=\"color: #0000FF; text-decoration: underline;\">lmp@icmet.ro<\/a>\n            <\/p>\n<\/p><\/div>\n<div>\n<p style=\"font-size: 1.1em; margin-bottom: 5px;\">Deputy Chief: <strong>Eng. Constantin IANCU<\/strong><\/p>\n<p style=\"margin: 0;\">\n                <strong>Phone:<\/strong> <a href=\"tel:0351402427\" style=\"color:#000;\">0351 402427<\/a><br \/>\n                <strong>e-mail:<\/strong> <a href=\"mailto:lmp@icmet.ro\" style=\"color: #0000FF; text-decoration: underline;\">lmp@icmet.ro<\/a>\n            <\/p>\n<\/p><\/div><\/div>\n<div id=\"referinte\" style=\"margin-bottom: 40px;\">\n<p style=\"font-weight: bold; font-size: 1.1em; margin-bottom: 10px;\">Reference list:<\/p>\n<p>\n            <img decoding=\"async\" src=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/pdf-icon.png\" alt=\"PDF Icon\" style=\"vertical-align: middle; margin-right: 5px;\"><br \/>\n            <a href=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/reference-list-for-high-power-testing-laboratory-for-electrical-equipment-hpl-icmet-craiova.pdf\" target=\"_blank\" rel=\"noopener\" style=\"text-decoration: underline; color: #0000FF;\"><br \/>\n                Download the document<br \/>\n            <\/a>\n        <\/p>\n<\/p><\/div>\n<div id=\"publicatii\" style=\"margin-bottom: 40px;\">\n<h2 style=\"background-color: #003366; color: white; padding: 10px; text-align: center; margin: 0; border-bottom: 1px solid #ccc; text-transform: uppercase;\">\n            PUBLISHED WORKS<br \/>\n        <\/h2>\n<div style=\"background-color: #fff; padding: 20px; font-size: 0.95em; line-height: 1.5; border: 1px solid #ddd;\">\n<h3 style=\"color: #003366; padding-bottom: 5px; margin-bottom: 15px; border-bottom: 1px solid #eee;\">Articles and International Conferences<\/h3>\n<h4 style=\"color: #555; margin-bottom: 10px; margin-top: 20px;\">Year 2012<\/h4>\n<ul style=\"padding-left: 20px; margin-bottom: 10px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">George Curcanu, Constantin ILINCA, Corneliu CHICIU \u2013 NEW ASPECTS REGARDING THE MODERNIZATION OF HIGH POWER LABORATORY OF ICMET-CRAIOVA TO ATTAIN THE TECHNICAL AND QUALITATIVE LEVEL CORRESPONDING TO EUROPEAN UNION REQUIREMENTS (International Conference on Renewable Energies and Power Quality (ICREPQ&#039;12), Santiago de Compostella \u2013 Spain, 2012)<\/li>\n<\/ul>\n<h4 style=\"color: #555; margin-bottom: 10px; margin-top: 20px;\">Year 2011<\/h4>\n<ul style=\"padding-left: 20px; margin-bottom: 10px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">George Curcanu, Constantin ILINCA, Corneliu CHICIU, Horia Ionescu \u2013 MODERNIZATION OF HIGH POWER LABORATORY TO FULFILL THE TECHNICAL AND QUALITATIVE CONDITIONS FOR TESTS ACCORDING TO STANDARDS IN FORCE (International Conference on Renewable Energies and Power Quality (ICREPQ&#039;11), Las Palmas de Gran Canaria \u2013 Spain, 2011)<\/li>\n<\/ul>\n<h4 style=\"color: #555; margin-bottom: 10px; margin-top: 20px;\">Year 2010<\/h4>\n<ul style=\"padding-left: 20px; margin-bottom: 10px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">George Curcanu, Horia Ionescu, Daniel Truta \u2013 ASPECTS REGARDING MODERNIZATION OF HIGH POWER LABORATORY FOR LIMITING THE EFFECTS DUE TO ELECTROMAGNETIC FIELDS ACCORDING TO EMC REQUIREMENTS (International Conference on Renewable Energies and Power Quality (ICREPQ&#039;10), Granada \u2013 Spain, 2010)<\/li>\n<li style=\"margin-bottom: 10px;\">George Curcanu, Horia Ionescu, Daniel Truta, Cornel Chiciu \u2013 ASPECTS CONCERNING THE MODERNIZATION OF THE HIGH POWER LABORATORY TO ACHIEVE THE TECHNICAL AND QUALITATIVE LEVEL CORRESPONDING TO THE REQUIREMENTS OF THE EUROPEAN UNION (FOREN 2010, Neptun \u2013 Romania, 2010)<\/li>\n<\/ul>\n<h4 style=\"color: #555; margin-bottom: 10px; margin-top: 20px;\">Year 2009<\/h4>\n<ul style=\"padding-left: 20px; margin-bottom: 10px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">George Curcanu, Ilie Sbora \u2013 CONSIDERATIONS REGARDING TESTING OF LOW VOLTAGE EQUIPMENT ENDOWED WITH CONTACTS FROM COMPOSITE MATERIALS TYPE CMC (International Conference on Renewable Energies and Power Quality (ICREPQ&#039;09 Valencia -Spain, 2009)<\/li>\n<li style=\"margin-bottom: 10px;\">George Curcanu \u2013 NEW ASPECTS REGARDING THE SWITCHING BEHAVIOR OF HIGH VOLTAGE SWITCHES WITH SF6 VS. VACUUM (National Conference and Exhibition of Energy, CNEE 2009, Sinaia-Romania, 2009)<\/li>\n<li style=\"margin-bottom: 10px;\">George Curcanu, Ilie Sbora - CONSIDERATION REGARDING INTERNAL ARC TEST ON 12 kV AND 24 kV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU - (&quot;Power and Energy System - ASIA PES 2009&quot; Conference, Beijing-China, 2009)<\/li>\n<\/ul>\n<h4 style=\"color: #555; margin-bottom: 10px; margin-top: 20px;\">Year 2008<\/h4>\n<ul style=\"padding-left: 20px; margin-bottom: 10px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">Curcanu George \u2013 ASPECTS REGARDING MAKING AND BREAKING TESTS OF LOW VOLTAGE EQUIPMENT ( WEC REGIONAL ENERGY FORUM FOREN 2008, Neptun-Olimp, Romania, 2008)<\/li>\n<li style=\"margin-bottom: 10px;\">Curcanu George, Ilinca Constantin, Iancu Constantin \u2013 RESEARCH, DEVELOPMENT AND TESTING NATIONAL INSTITUTE FOR ELECTRICAL ENGINEERING \u2013 ICMET CRAIOVA EXPERIENCE REGARDING TESTS ON MEDIUM VOLTAGE EQUIPMENT WITH VACUUM SWITCHING DEVICES (XXIII-rd International Symposium on Discharges and Electrical Insulation in Vacuum \u2013 ISDEIV 2008, Bucharest-Romania, 2008)<\/li>\n<li style=\"margin-bottom: 10px;\">Curcanu George, Iancu Constantin \u2013 CONSIDERATIONS REGARDING THE SHORT-CIRCUIT WITHSTAND TESTS OF POWER TRANSFORMERS (ICEM&#039;08- XVIII International Conference on Electrical Machines, Vilamoura (Algarve) \u2013 Portugal, 2008)<\/li>\n<\/ul>\n<h4 style=\"color: #555; margin-bottom: 10px; margin-top: 20px;\">Year 2007<\/h4>\n<ul style=\"padding-left: 20px; margin-bottom: 10px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">G. Curcanu, P. Tusaliu \u2013 TRANSIENTS PHENOMENA AT THE 400 kV NO-LOADED LINE SWITCHING (Electric Power Systems, High Voltages, Electric Machines (Power&#039; 07), Venice - Italy, 2007)<\/li>\n<li style=\"margin-bottom: 10px;\">George Curcanu, Constantin Iancu, Daniel Truta \u2013 CONSIDERATION REGARDING TESTING OF LOW VOLTAGE EQUIPMENT AT ELECTRIC ARC AND THERMAL FACTOR ACTIONS (International conference on renewable energies and power quality (ICREPQ&#039;07)&quot;, Sevilla-Spain, 2007)<\/li>\n<li style=\"margin-bottom: 10px;\">George Curcanu, Constantin Iancu, Daniel Truta \u2013 INSTALLATION FOR TESTING OF LOW VOLTAGE EQUIPMENT (National Conference and Exhibition of Energy \u2013 CNEE 2007, Sinaia-Romania, 2007)<\/li>\n<li style=\"margin-bottom: 10px;\">George Curcanu \u2013 INTERLABORATORY COMPARATIVE TESTS ON THE CALIBRATION OF THE SONGS FROM THE HIGH POWER LABORATORY OF ICMET CRAIOVA (National Conference and Exhibition on Energy \u2013 CNEE 2007, Sinaia-Romania, 2007)<\/li>\n<li style=\"margin-bottom: 10px;\">Andrei Marinescu, Cornel Chiciu, Horia Ionescu, Constantin Ilinca, Alexandru Ionescu \u2013 CALIBRATION LABORATORY OF HIGH CURRENT MEASURING DEVICES (1st International Proficiency Testing Conference, Sinaia-Romania, 2007)<\/li>\n<\/ul>\n<h4 style=\"color: #555; margin-bottom: 10px; margin-top: 20px;\">Year 2006<\/h4>\n<ul style=\"padding-left: 20px; margin-bottom: 10px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">Curcanu George \u2013 CONSIDERATION ON METAL OXIDE SURGE ARRESTERS AT SHORT-CIRCUIT CURRENT TEST (World Energy System Conference-Torino \u2013 WESC 2006)<\/li>\n<li style=\"margin-bottom: 10px;\">George Curcanu, Constantin Iancu, Cornel Chiciu \u2013 CONSIDERATIONS ON HIGH POWER ARC TESTING IN ALTERNATIVE CURRENT ON SINGLE AND DOUBLE SUPPORT CHAINS WITH COMPOSITE INSULATOR FOR OVERHEAD POWER LINES (FOREN 2006, WEC Regional Energy Forum, Neptun-Romania, 2006)<\/li>\n<li style=\"margin-bottom: 10px;\">Curcanu George, Toader Dumitru, Pandia Tanase \u2013 DETERMINATION OF OVERVOLTAGES IN HIGH VOLTAGE NETWORKS AT SINGLE PHASE FAULTS BY NUMERICAL SIMULATION AND EXPERIMENTS (12-th International IGTE Symposium, GRAZ, Austria, 2006)<\/li>\n<li style=\"margin-bottom: 10px;\">George Curcanu, Constantin Iancu, Cornel Chiciu \u2013 METHODS AND CIRCUITS FOR POWER ARC TEST IN AC CURRENT OF THE SIMPLE AND DOUBLE INSULATOR SERS WITH COMPOSITE MATERIAL FOR AERIAL ELECTRIC LINES (8-th International Conference of Applied and Theoretical Electricity ICATE 2006, Baile Herculane \u2013 Romania, 2006)<\/li>\n<li style=\"margin-bottom: 10px;\">Corneliu Chiciu, Horia Ionescu, Constantin Ilinca, Alexandru Ionescu \u2013 CONTRIBUTION ON THE DEMONSTRATION OF TRACEABILITY IN MEASURING HIGH CURRENTS (8-th International Conference of Applied and Theoretical Electricity ICATE 2006, Baile Herculane-Romania, 2006)<\/li>\n<\/ul>\n<h4 style=\"color: #555; margin-bottom: 10px; margin-top: 20px;\">Year 2005<\/h4>\n<ul style=\"padding-left: 20px; margin-bottom: 10px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">Corneliu Chiciu, Ilie Sbora, Constantin Ilinca, - BEHAVIOR OF THE EQUIPMENT IN THE METAL CASE AND OF THE TRANSFORMATION STATIONS UNDER THE ACTION OF THE INTERNAL ELECTRIC ARC (Romanian Electrical Engineering Week, Craiova \u2013 Romania, 2005)<\/li>\n<li style=\"margin-bottom: 10px;\">Curcanu George \u2013 MONITORING OF DEFECTS IN THE CONTROL AND COMMAND SYSTEMS OF SF6 CIRCUIT BREAKERS (XIXth edition of the NATIONAL SYMPOSIUM &quot;ENERGY SYSTEM SAFETY&quot; \u2013 SIG 2005, Sinaia-Romania, 2005)<\/li>\n<li style=\"margin-bottom: 10px;\">Curcanu George \u2013 SCHEMES AND METHODS FOR TESTING LOW VOLTAGE CIRCUIT BREAKERS AND SEPARATORS FOR SWITCHING CAPACITIVE CURRENTS IN THE LABORATORY AND THE NETWORK (PSC Timisoara, Romania, 2005)<\/li>\n<\/ul>\n<h4 style=\"color: #555; margin-bottom: 10px; margin-top: 20px;\">Year 2004<\/h4>\n<ul style=\"padding-left: 20px; margin-bottom: 10px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">Cornel Chiciu \u2013 ICMET CRAIOVA HIGH POWER LABORATORY \u2013 PRESENT AND PERSPECTIVE (National Energy Conference CNE 2004, &quot;Sustainable Energy Development and European Integration&quot;, Neptun, Romania, 2004)<\/li>\n<li style=\"margin-bottom: 10px;\">George Curcanu \u2013 CONSIDERATIONS ON TESTS OF METAL-OXIDE ARRESTORS AT SHORT-CIRCUIT CURRENTS (National Energy Conference CNE 2004, &quot;Sustainable Energy Development and European Integration&quot;, Neptun-Romania, 2004)<\/li>\n<\/ul>\n<h4 style=\"color: #555; margin-bottom: 10px; margin-top: 20px;\">Year 2003<\/h4>\n<ul style=\"padding-left: 20px; margin-bottom: 10px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">George Curcanu \u2013 INFLUENCE OF INTERNAL ELECTRIC ARC ON THE DEMANDS IN SPDs AND CURRENT TRANSFORMERS DURING SHORT-CIRCUIT CURRENT (5th International Conference on Electropower, Timisoara -Romania, 2003)<\/li>\n<li style=\"margin-bottom: 10px;\">George Curcanu, Eng. Horia Ionescu, Eng. Tanase Pandia \u2013 EXPERIMENTS FOR INTERNAL OVERVOLTAGES DETERMINATION IN MEDIUM VOLTAGES NETWORKS AT SINGLE-PHASE FAULT (XIII International Symposium on Electrical Equipment and Technologies, Plovdiv, Bulgaria, 2003)<\/li>\n<\/ul>\n<h4 style=\"color: #555; margin-bottom: 10px; margin-top: 20px;\">Year 2002<\/h4>\n<ul style=\"padding-left: 20px; margin-bottom: 10px; list-style-type: disc;\">\n<li style=\"margin-bottom: 10px;\">George Curcanu \u2013 DIAGNOSTIC AND MONITORING TECHNOLOGIES FOR ELECTRICAL SWITCHING APPARATUS NETWORK (8th International Conference &quot;Optimization of Electrical and Electronic Equipment OPTIM 2002&quot;, Brasov -Romania, 2002)<\/li>\n<li style=\"margin-bottom: 10px;\">Cornel Chuciu, Constantin Ilinca, Alexandru Manta \u2013 CONTRIBUTIONS ON THE EVALUATION OF THE BEHAVIOR OF ELECTRICAL POWER EQUIPMENT UNDER THE ACTION OF INTERNAL ELECTRIC ARC (National Energy Conference CNE 2002, Neptun-Romania 2002)<\/li>\n<li style=\"margin-bottom: 10px;\">Cornel Chiciu \u2013 CIRCUITS AND METHOD FOR INTERNAL ELECTRIC ARC TESTING AT INSTRUMENT TRANSFORMERS (Einlandung zum Seminar Elektroenergiesysteme ung Hochspannungstechnik, Karlsruhe \u2013 Germany, 2002)<\/li>\n<li style=\"margin-bottom: 10px;\">George Curcanu \u2013 NUMERICAL MODELING OF TRANSIENT OVERVOLTAGE SHUNT REACTOR CURRENT SWITCHING IN 400 KV NETWORK (IGTE Symposium Gratz \u2013 Austria, 2002)<\/li>\n<\/ul>\n<h3 style=\"color: #003366; padding-bottom: 5px; margin-bottom: 15px; border-bottom: 1px solid #eee;\">Participation in National Symposia<\/h3>\n<h4 style=\"font-size: 1.05em; font-weight: bold; margin-bottom: 10px; color: #333; margin-top: 20px;\">First National Symposium (2009)<\/h4>\n<p style=\"font-style: italic; font-size: 0.9em; margin-bottom: 10px;\">\u201e&quot;Application of optoelectronic measurement and monitoring methods in the Romanian energy system&quot;, May 6-8, 2009, Cheia-Romania<\/p>\n<ul style=\"padding-left: 20px; margin-bottom: 20px; list-style-type: disc;\">\n<li style=\"margin-bottom: 5px;\">Alexandru Manta, Andrei Marinescu, Teodor Popa, Marinel Popescu \u2013 OPTOELECTRONIC HYBRID INSTRUMENT TRANSFORMER WITH DIGITAL OUTPUT COMPATIBLE WITH IEC 61850-9-2<\/li>\n<li style=\"margin-bottom: 5px;\">Andrei Marinescu, Alexandru Manta, Daniel Truta \u2013 FO MONITORING OF MOV PROTECTION DEVICES FOR POWER AUTOTRANSFORMERS<\/li>\n<li style=\"margin-bottom: 5px;\">Costel Caramida, Horia Ionescu, Andrei Marinescu, Daniel Truta, Alin Dinca, Alexandru Manta \u2013 FIBER OPTIC APPLICATIONS IN COMMANDS AND INFORMATION TRANSMISSION REALIZED WITHIN ICMET INSTITUTE<\/li>\n<\/ul>\n<h4 style=\"font-size: 1.05em; font-weight: bold; margin-bottom: 10px; color: #333; margin-top: 20px;\">Second International Symposium (2004)<\/h4>\n<p style=\"font-style: italic; font-size: 0.9em; margin-bottom: 10px;\">SIMC-EE 2004, October 14-15, 2004, Baile Herculane \u2013 Romania<\/p>\n<ul style=\"padding-left: 20px; margin-bottom: 20px; list-style-type: disc;\">\n<li style=\"margin-bottom: 5px;\">Cornel Chiciu, Constantin Ilinca \u2013 THE HIGH POWER LABORATORY IN CRAIOVA. 30 YEARS SINCE ITS ESTABLISHMENT<\/li>\n<li style=\"margin-bottom: 5px;\">Alexandru Manta, Andrei Marinescu, Horia Ionescu, Daniel Truta \u2013 MEASUREMENT OF TRANSIENT PHENOMENA UNDER HIGH POTENTIAL BY OPTOELECTRONIC MEANS<\/li>\n<li style=\"margin-bottom: 5px;\">George Curcanu, Constantin Comes, M. Constantinov \u2013 CONSIDERATIONS REGARDING THE TESTING OF MEDIUM VOLTAGE CIRCUIT BREAKERS AT CAPACITIVE CURRENTS, IN ACCORDANCE WITH THE REGULATIONS OF CEI 62271-100<\/li>\n<li style=\"margin-bottom: 5px;\">George Curcanu, Constantin Comes, I. Constantin \u2013 SWITCHING OF SMALL INDUCTIVE CURRENTS WHEN DISCONNECTING NO-LOAD TRANSFORMERS USING HIGH VOLTAGE CIRCUIT BREAKERS<\/li>\n<li style=\"margin-bottom: 5px;\">George Curcanu, Cornel Chiciu, Constantin Ilinca, M. Constantinov \u2013 CONSIDERATIONS ON METAL-OXIDE ARRESTORS IN SHORT-CIRCUIT CURRENT TESTING<\/li>\n<li style=\"margin-bottom: 5px;\">Constantin Iancu, Constantin Ilinca, Alexandru Manta, Ilie Diaconescu, D. Stancu, Paul Ilinca \u2013 EXCITATION REGIME OF THE TI-100-2 SHOCK GENERATOR TYPE IN THE HIGH POWER LABORATORY<\/li>\n<li style=\"margin-bottom: 5px;\">Constantin Ilina, Cornel Chiciu, Ilinca Sbora \u2013 BEHAVIOR OF THE EQUIPMENT IN THE METAL CASE AND OF THE TRANSFORMATION STATIONS UNDER THE ACTION OF THE INTERNAL ELECTRIC ARC<\/li>\n<li style=\"margin-bottom: 5px;\">Horia Ionescu, George Curcanu, Cornel Chiciu, Constantin Ilinca, Daniel Truta, Mihai Ionescu, Andrei Marinescu, Alexandru Manta \u2013 MODERNIZATION OF MEASUREMENT TECHNIQUE IN THE HIGH POWER LABORATORY<\/li>\n<\/ul>\n<h4 style=\"font-size: 1.05em; font-weight: bold; margin-bottom: 10px; color: #333; margin-top: 20px;\">Third International Symposium (2007)<\/h4>\n<p style=\"font-style: italic; font-size: 0.9em; margin-bottom: 10px;\">November 26-28, 2007 Baile Olanesti-Romania<\/p>\n<ul style=\"padding-left: 20px; margin-bottom: 20px; list-style-type: disc;\">\n<li style=\"margin-bottom: 5px;\">Alexandru Manta, Andrei Marinescu, Constantin Iancu, Alin Dinca \u2013 MEASUREMENT OF TRANSIENT HIGH CURRENTS THROUGH ROGOWSKI TECHNIQUE<\/li>\n<li style=\"margin-bottom: 5px;\">Andrei Marinescu, Alexandru Manta, Horia Ionescu, Daniel Truta, Mihai Ionescu, Alin Dinca, Mihaela Iovan -MODERNISATION OF MEASURING TECHNIQUE WITHIN ICMET HIGH POWER LABORATORY BY TRANSIENT RECORDER UTILIZATION<\/li>\n<li style=\"margin-bottom: 5px;\">Alexandru Manta, Alin Dinca, Costel Caramida, Horia Ionescu \u2013 A NEW SEQUENTIAL PROGRAMMER SYSTEM FROM HIGH POWER LABORATORY<\/li>\n<li style=\"margin-bottom: 5px;\">George Curcanu, Horia Ionescu, Daniel Truta \u2013 ASPECTS REGARDING LOW VOLTAGE EQUIPMENT TESTS IN ICMET HIGH POWER LABORATORY<\/li>\n<li style=\"margin-bottom: 5px;\">George Curcanu \u2013 FAILURE MONITORING FOR THE CONTROL-COMMAND SYSTEM OF SF6 CIRCUIT BREAKERS<\/li>\n<li style=\"margin-bottom: 5px;\">George Curcanu, Constantin Iancu \u2013 CONSIDERATION REGARDING SHORT-CIRCUIT TEST OF RECLOSER CIRCUIT-BREAKER<\/li>\n<li style=\"margin-bottom: 5px;\">Horia Ionescu, Andrei Marinescu, Mihai Ionescu, Daniel Truta, Mihaela Iovan \u2013 TRACEABILITY OF THE SYSTEMS FOR MEASURING THE SPECIFIC PHENOMENA TO HIGH POWER LABORATORY<\/li>\n<li style=\"margin-bottom: 5px;\">Alexandru Manta, Andrei Marinescu, Horia Ionescu, Daniel Truta, Alin Dinca \u2013 MEASUREMENT OF HIGH POTENTIAL TRANSIENT PHENOMENA BY OPTOELECTRONIC MEANS<\/li>\n<li style=\"margin-bottom: 5px;\">Cornel Chiciu, Horia Ionescu, Alexandru Ionescu \u2013 CALIBRATION OF HIGH CURRENT MEASURING SYSTEMS<\/li>\n<\/ul>\n<h4 style=\"font-size: 1.05em; font-weight: bold; margin-bottom: 10px; color: #333; margin-top: 20px;\">SMDEE Symposium (2007)<\/h4>\n<p style=\"font-style: italic; font-size: 0.9em; margin-bottom: 10px;\">\u201e&quot;Progress in monitoring and diagnosis of electrical power equipment&quot; (first edition), November 26-28, Baile Olanesti-Romania<\/p>\n<ul style=\"padding-left: 20px; margin-bottom: 20px; list-style-type: disc;\">\n<li style=\"margin-bottom: 5px;\">Andrei Marinescu, Alexandru Manta, Daniel Truta, Constantin Iancu \u2013 MONITORING OF MOV PROTECTION DEVICES FOR POWER AUTOTRANSFORMERS<\/li>\n<\/ul><\/div><\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Laborator de Incercari de Mare Putere pentru Echipamente Electrotehnice Persoana de contact Incercari Servicii oferite Referinte Publicatii Prezentare Generala LMP &#9658; Click pentru a viziona prezentarea video a Laboratorului de Mare Putere. Laboratorul a fost acreditat de: Reteaua Nationala de Acreditare din Romania &#8211; RENAR. Membra ILAC si EA. Acreditare conform EN ISO\/IEC 17025:2005. Membru international: CIGRE WG 13.12 LOVAG Registred Laboratory Certificare RENAR Click pentru a vizualiza certificatul complet (PDF) Click pentru a deschide documentul (PDF) Parametrii incercarilor la curentii de scurtcircuit: Trifazat Monofazat 12 kV &#8211; 170 kA 12 kV &#8211; 170 kA 72.5 kV &#8211; 25 kA 123 kV &#8211; 25 kA170 kV &#8211; 15 kA Parametrii incercarilor la curent admisibil de scurta durata: Trifazat Monofazat 500 V &#8211; 135 kA\/5s 500 V &#8211; 320 kA\/5s 860 V &#8211; 80 kA\/5s 2000 V &#8211; 80 kA\/5s Finantare nerambursabila din Fondul European de Dezvoltare Regionala. Pentru Laboratorul de Mare Putere ICMET Craiova. SCHEMA DE INCERCARE DIRECTA Generatoare: Trei unitati de scurt-circuit. Fiecare are 2500 MVA. Curentul este 120 kA pentru 0,5 s. Functioneaza in paralel. Protectie: Sase unitati trifazate de intreruptoare. Parametrii sunt 12 kV si 120 kA. Scurtcircuitoare: Noua unitati monofazate. Parametrii sunt 12 kV si 330 kA. Transformatoare ridicatoare: Noua unitati monofazate de 600 MVA. Rapoarte 12\/12\/25\/51 kV. Transformatoare coboratoare: Patru unitati monofazate de 40 MVA. Rapoarte multiple. Celule: Opt celule de incercare disponibile. Condensatoare: Baterie pentru incercare directa. Trifazat 36 kV si 400 A. Incalzire: Instalatie de incercare la incalzire. Pana la 10 000 A in c.a. Pantograf: Instalatie separator de IT. Parametri 525 kV si 60 kA\/1s. Arc de putere: Instalatie in c.a. Pentru lanturi de izolatoare de 420 kV. Digital: Sistem de Masurare Digital 100 MS\/s. Are 16bit si 24 canale. SERVICII OFERITE Incercari Standard si de Comutatie Incercarea capacitatii de comutatie a intreruptoarelor si separatoarelor de MT si JT. Se testeaza si capacitatea de rupere a sigurantelor fuzibile. Incercari de stabilitate termica si dinamica. Acestea se aplica aparatelor de IT si JT, cablurilor si celulelor. Incercarea stabilitatii dinamice la scurtcircuit a transformatoarelor de putere. Limita este pana la 120 MVA. Incercari de comutatie la curenti inductivi si capacitivi. Se aplica intreruptoarelor si separatoarelor de sarcina. Incercarea de anduranta mecanica pentru intreruptoare, separatoare si contactoare. Incercari Speciale si de Incalzire Incercari de incalzire a cailor de curent a aparatelor electrice si barelor. Curent nominal maxim 10 kA c.a. Incercari de incalzire la transformatoarele de putere, transformatoarele de masura si reactoare. Incercari de scurt-circuit ale descarcatoarelor, armaturilor si motoarelor. Se testeaza si sistemele de pamantare. Incercari speciale la arc de putere. Se fac pe linii de izolatoare. Include arc electric intern. Incercari de mare putere on site Masurarea supratensiunii de comutare la deconectarea sarcinilor inductive si capacitive. Se aplica in retelele pana la 420 kV. Masurarea tensiunilor induse in sarcina la scurt-circuit pe LEA cu tensiuni pana la 420 kV. Sef laborator: Ing. Daniel TRUTA Telefon: 0351 402427; 0351 404888 e-mail: lmp@icmet.ro Sef Adjunct: Ing. Constantin IANCU Telefon: 0351 402427 e-mail: lmp@icmet.ro Lista de referinte: Descarca documentul LUCRARI PUBLICATE Articole si Conferinte Internationale Anul 2012 George Curcanu, Constantin ILINCA, Corneliu CHICIU &#8211; NEW ASPECTS REGARDING THE MODERNISATION OF HIGH POWER LABORATORY OF ICMET-CRAIOVA TO ATTAIN THE TECHNICAL AND QUALITATIVE LEVEL CORRESPONDING TO EUROPEAN UNION REQUIREMENTS (International Conference on Renewable Energies and Power Quality (ICREPQ&#8217;12), Santiago de Compostella &#8211; Spain, 2012) Anul 2011 George Curcanu, Constantin ILINCA, Corneliu CHICIU, Horia Ionescu &#8211; MODERNISATION OF HIGH POWER LABORATORY TO FULFILL THE TECHNICAL AND QUALITATIVE CONDITIONS FOR TESTS ACCORDING TO STANDARDS IN FORCE (International Conference on Renewable Energies and Power Quality (ICREPQ&#8217;11), Las Palmas de Gran Canaria &#8211; Spain, 2011) Anul 2010 George Curcanu, Horia Ionescu, Daniel Truta &#8211; ASPECTS REGARDING MODERNISATION OF HIGH POWER LABORATORY FOR LIMITING THE EFFECTS DUE TO ELECTROMAGNETIC FIELDS ACCORDING TO EMC REQUIREMENTS (International Conference on Renewable Energies and Power Quality (ICREPQ&#8217;10), Granada &#8211; Spain, 2010) George Curcanu, Horia Ionescu, Daniel Truta, Cornel Chiciu &#8211; ASPECTE PRIVIND MODERNIZAREA LABORATORULUI DE MARE PUTERE PENTRU ATINGEREA NIVELULUI TEHNIC SI CALITATIV CORESPUNZATOR CERINTELOR UNIUNII EUROPENE (FOREN 2010, Neptun &#8211; Romania, 2010) Anul 2009 George Curcanu, Ilie Sbora &#8211; CONSIDERATIONS REGARDING TESTING OF LOW VOLTAGE EQUIPMENT ENDOWED WITH CONTACTS FROM COMPOSITE MATERIALS TYPE CMC (International Conference on Renewable Energies and Power Quality (ICREPQ&#8217;09 Valencia -Spain, 2009) George Curcanu &#8211; ASPECTE NOI PRIVIND COMPORTAREA LA COMUTATIE A INTRERUPTOARELOR DE INALTA TENSIUNE CU SF6 VS. VACUUM (Conferinta Nationala si Expozitia de Energetica, CNEE 2009, Sinaia-Romania, 2009) George Curcanu, Ilie Sbora &#8211; CONSIDERATION REGARDING INTERNAL ARC TEST ON 12 kV AND 24 kV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU &#8211; (Conferinta &#8222;Power and Energy System &#8211; ASIA PES 2009&#8221;, Beijing-China, 2009) Anul 2008 Curcanu George &#8211; ASPECTS REGARDING MAKING AND BREAKING TESTS OF LOW VOLTAGE EQUIPMENT ( WEC REGIONAL ENERGY FORUM FOREN 2008, Neptun-Olimp, Romania, 2008) Curcanu George, Ilinca Constantin, Iancu Constantin &#8211; RESEARCH, DEVELOPMENT AND TESTING NATIONAL INSTITUTE FOR ELECTRICAL ENGINEERING &#8211; ICMET CRAIOVA EXPERIENCE REGARDING TESTS ON MEDIUM VOLTAGE EQUIPMENT WITH VACUUM SWITCHING DEVICES (XXIII-rd International Symposium on Discharges and Electrical Insulation in Vacuum &#8211; ISDEIV 2008, Bucuresti-Romania, 2008) Curcanu George, Iancu Constantin &#8211; CONDSIDERATIONS REGARDING THE SHORT-CIRCUIT WITHSTAND TESTS OF POWER TRANSFORMERS (ICEM&#8217;08- XVIII International Conference on Electrical Machines, Vilamoura (Algarve) &#8211; Portugal, 2008) Anul 2007 G. Curcanu, P. Tusaliu &#8211; TRANSIENTS PHENOMENA AT THE 400 kV NO-LOADED LINE SWITCHING (Electric Power Systems, High Voltages, Electric Machines (Power&#8217; 07), Venetia -Italia, 2007) George Curcanu, Constantin Iancu, Daniel Truta &#8211; CONSIDERATION REGARDING TESTING OF LOW VOLTAGE EQUIPMENT AT ELECTRIC ARC AND THERMAL FACTOR ACTIONS (International conference on renewable energies and power quality (ICREPQ&#8217;07)&#8221;, Sevilla-Spania, 2007) George Curcanu, Constantin Iancu, Daniel Truta &#8211; INSTALLATION FOR TESTING OF LOW VOLTAGE EQUIPMENT (Conferinta Nationala si Expozitia de Energetica &#8211; CNEE 2007, Sinaia-Romania, 2007) George Curcanu &#8211; INCERCARI COMPARATIVE INTERLABORATOARE PRIVIND CALIBRAREA SUNTURILOR DIN LABORATORUL DE MARE PUTERE AL ICMET CRAIOVA (Conferinta Nationala si Expozitia de Energetica &#8211; CNEE 2007, Sinaia-Romania, 2007) Andrei Marinescu , Cornel Chiciu, Horia Ionescu, Constantin Ilinca, Alexandru Ionescu &#8211; LABORATOR DE ETALONARE A DISPOZITIVELOR DE MASURARE [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":3207,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3212","page","type-page","status-publish","hentry","post-no-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Laborator Incercari Mare Putere LMP - ICMET Craiova<\/title>\n<meta name=\"description\" content=\"Laborator Incercari Mare Putere (LMP) ICMET. Teste scurtcircuit si capacitate rupere echipamente electrotehnice. Acreditat RENAR.\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Laborator Incercari Mare Putere LMP - ICMET Craiova\" \/>\n<meta property=\"og:description\" content=\"Laborator Incercari Mare Putere (LMP) ICMET. Teste scurtcircuit si capacitate rupere echipamente electrotehnice. Acreditat RENAR.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/icmet.wattmedia.ro\/en\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/laborator-incercari-mare-putere-lmp\/\" \/>\n<meta property=\"og:site_name\" content=\"ICMET\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-12T14:17:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/high-power-laboratory-icmet-craiova.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"13 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/structura-organizatorica\\\/departament-cercetare-dezvoltare\\\/divizia-mare-putere\\\/laborator-incercari-mare-putere-lmp\\\/\",\"url\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/structura-organizatorica\\\/departament-cercetare-dezvoltare\\\/divizia-mare-putere\\\/laborator-incercari-mare-putere-lmp\\\/\",\"name\":\"Laborator Incercari Mare Putere LMP - ICMET Craiova\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/structura-organizatorica\\\/departament-cercetare-dezvoltare\\\/divizia-mare-putere\\\/laborator-incercari-mare-putere-lmp\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/structura-organizatorica\\\/departament-cercetare-dezvoltare\\\/divizia-mare-putere\\\/laborator-incercari-mare-putere-lmp\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/high-power-laboratory-icmet-craiova.jpg\",\"datePublished\":\"2026-02-11T11:14:00+00:00\",\"dateModified\":\"2026-03-12T14:17:08+00:00\",\"description\":\"Laborator Incercari Mare Putere (LMP) ICMET. Teste scurtcircuit si capacitate rupere echipamente electrotehnice. Acreditat RENAR.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/structura-organizatorica\\\/departament-cercetare-dezvoltare\\\/divizia-mare-putere\\\/laborator-incercari-mare-putere-lmp\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/icmet.wattmedia.ro\\\/structura-organizatorica\\\/departament-cercetare-dezvoltare\\\/divizia-mare-putere\\\/laborator-incercari-mare-putere-lmp\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/structura-organizatorica\\\/departament-cercetare-dezvoltare\\\/divizia-mare-putere\\\/laborator-incercari-mare-putere-lmp\\\/#primaryimage\",\"url\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/high-power-laboratory-icmet-craiova.jpg\",\"contentUrl\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/wp-content\\\/uploads\\\/2026\\\/02\\\/high-power-laboratory-icmet-craiova.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/structura-organizatorica\\\/departament-cercetare-dezvoltare\\\/divizia-mare-putere\\\/laborator-incercari-mare-putere-lmp\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Prima pagin\u0103\",\"item\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Structura\",\"item\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/structura-organizatorica\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Departament C-D incercari, etalonari\",\"item\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/structura-organizatorica\\\/departament-cercetare-dezvoltare\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Divizia Mare Putere\",\"item\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/structura-organizatorica\\\/departament-cercetare-dezvoltare\\\/divizia-mare-putere\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Laborator Incercari de Mare Putere pentru echipamente electrotehnice\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/#website\",\"url\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/\",\"name\":\"ICMET\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/icmet.wattmedia.ro\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Laborator Incercari Mare Putere LMP - ICMET Craiova","description":"Laborator Incercari Mare Putere (LMP) ICMET. Teste scurtcircuit si capacitate rupere echipamente electrotehnice. Acreditat RENAR.","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_US","og_type":"article","og_title":"Laborator Incercari Mare Putere LMP - ICMET Craiova","og_description":"Laborator Incercari Mare Putere (LMP) ICMET. Teste scurtcircuit si capacitate rupere echipamente electrotehnice. Acreditat RENAR.","og_url":"https:\/\/icmet.wattmedia.ro\/en\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/laborator-incercari-mare-putere-lmp\/","og_site_name":"ICMET","article_modified_time":"2026-03-12T14:17:08+00:00","og_image":[{"url":"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/high-power-laboratory-icmet-craiova.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"13 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/icmet.wattmedia.ro\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/laborator-incercari-mare-putere-lmp\/","url":"https:\/\/icmet.wattmedia.ro\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/laborator-incercari-mare-putere-lmp\/","name":"Laborator Incercari Mare Putere LMP - ICMET Craiova","isPartOf":{"@id":"https:\/\/icmet.wattmedia.ro\/#website"},"primaryImageOfPage":{"@id":"https:\/\/icmet.wattmedia.ro\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/laborator-incercari-mare-putere-lmp\/#primaryimage"},"image":{"@id":"https:\/\/icmet.wattmedia.ro\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/laborator-incercari-mare-putere-lmp\/#primaryimage"},"thumbnailUrl":"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/high-power-laboratory-icmet-craiova.jpg","datePublished":"2026-02-11T11:14:00+00:00","dateModified":"2026-03-12T14:17:08+00:00","description":"Laborator Incercari Mare Putere (LMP) ICMET. Teste scurtcircuit si capacitate rupere echipamente electrotehnice. Acreditat RENAR.","breadcrumb":{"@id":"https:\/\/icmet.wattmedia.ro\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/laborator-incercari-mare-putere-lmp\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/icmet.wattmedia.ro\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/laborator-incercari-mare-putere-lmp\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/icmet.wattmedia.ro\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/laborator-incercari-mare-putere-lmp\/#primaryimage","url":"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/high-power-laboratory-icmet-craiova.jpg","contentUrl":"https:\/\/icmet.wattmedia.ro\/wp-content\/uploads\/2026\/02\/high-power-laboratory-icmet-craiova.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/icmet.wattmedia.ro\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/laborator-incercari-mare-putere-lmp\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Prima pagin\u0103","item":"https:\/\/icmet.wattmedia.ro\/"},{"@type":"ListItem","position":2,"name":"Structura","item":"https:\/\/icmet.wattmedia.ro\/structura-organizatorica\/"},{"@type":"ListItem","position":3,"name":"Departament C-D incercari, etalonari","item":"https:\/\/icmet.wattmedia.ro\/structura-organizatorica\/departament-cercetare-dezvoltare\/"},{"@type":"ListItem","position":4,"name":"Divizia Mare Putere","item":"https:\/\/icmet.wattmedia.ro\/structura-organizatorica\/departament-cercetare-dezvoltare\/divizia-mare-putere\/"},{"@type":"ListItem","position":5,"name":"Laborator Incercari de Mare Putere pentru echipamente electrotehnice"}]},{"@type":"WebSite","@id":"https:\/\/icmet.wattmedia.ro\/#website","url":"https:\/\/icmet.wattmedia.ro\/","name":"ICMET","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/icmet.wattmedia.ro\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/icmet.wattmedia.ro\/en\/wp-json\/wp\/v2\/pages\/3212","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/icmet.wattmedia.ro\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/icmet.wattmedia.ro\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/icmet.wattmedia.ro\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/icmet.wattmedia.ro\/en\/wp-json\/wp\/v2\/comments?post=3212"}],"version-history":[{"count":25,"href":"https:\/\/icmet.wattmedia.ro\/en\/wp-json\/wp\/v2\/pages\/3212\/revisions"}],"predecessor-version":[{"id":4558,"href":"https:\/\/icmet.wattmedia.ro\/en\/wp-json\/wp\/v2\/pages\/3212\/revisions\/4558"}],"up":[{"embeddable":true,"href":"https:\/\/icmet.wattmedia.ro\/en\/wp-json\/wp\/v2\/pages\/3207"}],"wp:attachment":[{"href":"https:\/\/icmet.wattmedia.ro\/en\/wp-json\/wp\/v2\/media?parent=3212"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}